Panasonic AW-E800 User Manual

Page 42

Advertising
background image

-40-

• In case of using the RCU (RCB), none of the shut-

ter speeds–1/250, 1/2 000, 1/4 000, and 1/10 000
can be selected.

• In case of using the hybrid control panel, only

OFF, 1/100, or ELC can be selected.

• If the lens iris switch is at M (Manual) when oper-

ating the camera alone or when the iris switch on
the RCU (RCB) is at AUTO, ELC may not function.
Set the lens iris switch to A (Auto).

• Flickering may increase at ELC under fluorescent

lights.

Notes

#2

Electronic Shutter Mode Setting [Shutter Mode:
Step/ELC/S/Scan]
Step:

Electronic shutter operates at the speed

selected by the Electronic Shutter Step Setting
#3.

ELC:

Electronic shutter is controlled to automatical-

ly adjust the luminance.

S/Scan (Synchro Scan):

Electronic shutter oper-

ates at the speed selected in Electronic Shutter
Synchro-Scan Setting

#4.

#3

Electronic Shutter Step Setting
[Step: OFF/1/100 - 1/10 000]

This setting is possible only when Step is selected
in Electronic Shutter Mode Setting

#2.

OFF:

Electronic shutter is turned off.

1/100, 1/250, 1/500, 1/1 000, 1/2 000, 1/4 000,
1/10 000:

Electronic shutter operates at one of

these speeds as selected.

#4

Electronic Shutter Synchro Scan Setting
[Synchro Scan: 60.58Hz - 15.75kHz]

This setting is possible only when Electronic Shutter
Mode Setting

#2 is at S/Scan.

Bar noise can be reduced by synchro-scan adjust-
ment in shooting workstation scenes, for example.

* For luminance setting at each shutter speed and

synchro-scan shutter speed, refer to the table on the
next page.

If Frame 1 is selected in CCD Read Out Mode
Setting

#5, Electronic Shutter Mode Setting cannot

be added.

Note

Advertising