Patton electronic 1088/K User Manual

Page 13

Advertising
background image

13

• Set the Model 1088 (CP) to “NetLink Plug-and-Play CP” by setting S1

and S2 DIP switches in the ON position as described in Figure 3.

Figure 3.

Typical NetLink Plug-and-Play Application

When the CO and CP units connect over DSL, the CP will enter a pre-
defined default configuration (Receive Recovered Clocking). During the
negotiation process between the units, the CO unit will configure the
DTE rate/line rate on the CP unit as defined by the settings of the CO
unit. When additional bandwidth is required, only the configuration of the
CO unit should be changed. This feature gives ISPs, LECs and PTTs the
ability to provision bandwidth on an as needed basis to customers.

The NetLink Plug and Play application will also work in an HTTP/SNMP
managed system using the NetLink Model 1001MC SNMP agent card
with 1095RC cards installed in Patton’s 2U rack system. In this applica-
tion, the system administrator can configure the entire rack through the
Network Management Station (NMS) before the stand alone (CP) units
are installed. For more information on the HTTP/SNMP management,
please refer to the Model 1001MC Operations Manual.

1095RC

(CO)

1088

(CP)

DIP Switches all in ON position

DIP Switches or NMS configured

according to specific application

requirements

DSL Span