5.0 OPERATION

Once the Model 1088 is properly configured and installed, it should oper-
ate transparently. This sections describes power-up, reading the LED
status monitors, and using the built-in loopback test modes.

5.1 POWER-UP

To apply power to the Model 1088, first be sure that you have read sec-
tion 4.3, “Connect Twisted-Pair DSL Interface” on page 16, and that the
unit is connected to the appropriate power source.

5.2 LED STATUS MONITORS

The Model 1088 features six front panel LEDs that monitor power, the
DTE signals, network connection and test modes. Figure 10 shows the
front panel location of each LED. Following Figure 10 is a description of
each LEDs function. See also APPENDIX E.

Figure 10.

Model 1088/K Front Panel

DSL LInk

(Active Green) Solid green (On) indicates that the
end to end DSL Framer Link is up, signifying that
the link across the DSL span is active. The DSL
Link LED is Off when the link is down.

E1/FE1
Link

(Active Green) Solid green (On) indicates a valid
E1 connection.

LOS

(Active Red) The Loss of Sync indicates that the
unit has lost synchronization with the incoming sig-
nal. This may happen when there is a framing mis-
match or a loss of signal. In unframed mode, the
LOS LED monitors the status of the transmit clock.

NS

(Active Red) The No Signal LED glows red to indi-
cate that the local Model 1088 is not connected
with the remote Model 1088.