Piping insulation, Precautions when bending pipes, Flare fitting connection – Philips Comfort-Cire AMC Series User Manual

Page 8

Advertising
background image

PIPING INSULATION

Liquid and suction lines must be insulated
separately. In a cooling only type air
conditioner, both pipes become cold during
operation. This can cause moisture to
condense on the surface of the pipes,
resulting in heat loss.

PRECAUTIONS WHEN BENDING
PIPES

!

The air conditioner's performance
will suffer if the piping is crushed.

!

Bend pipes using the pads of your
thumbs to prevent them from
collapsing (See picture on the right.)

!

Use a pipe bending tool to bend pipe
wider than 1/2" in diameter.

(a) DRY: Never allow any water to get
inside the piping.

(b) CLEAN: Never allow dirt, sand or other
foreign particles to get inside the piping.

Cap

Keep cap attached until immediately

before making piping connections.

Cap

Keep cap attached until immediately

before making piping connections.

FLARE FITTING CONNECTION.

There are 3 piping rules:

Bend with pads of thumbs

Pipe bending tool

b/a = 0.7 or more

Insulation

Narrow Pipe

Wide Pipe

Common insulation

Separate insulation is essential