Panasonic WV-NP244 User Manual

Page 29

Advertising
background image

29

Configure the settings relating to the alarm image [Alarm image setup]

Click the [Alarm] tab on the "Alarm setup" page. (

☞ page 16)

The settings relating to the alarm image to be transmitted to the FTP server can be configured on this page. The
alarm image will be transmitted to the FTP server. To transmit alarm images to the FTP server, it is necessary to
configure the settings in advance. (

☞ page 38)

Refer to pages 29 and 30 for further information about the settings relating to the alarm image and the alarm out
connector.

Important:

Depending on the network line speed or the network
traffic, images may not be transmitted at the exact
designated interval or period.

[Alarm image FTP transmission]
Select "ON" or "OFF" to determine whether or not to
transmit the alarm image to the FTP server.
Default: OFF

[Directory]
Enter the directory name where the alarm images are to
be saved.
For example, enter "/ALARM" to designate the directory
"ALARM" under the FTP root directory.
Number of characters for the directory name: 0 - 256

characters

[File name]
Enter the file name used for the alarm image to be
transmitted to the FTP server. The file name will be as
follows.
["Entered file name" + "Time and date (year/month/day/
hour/minute/second)"] + "Serial number"
Number of characters for the camera location: 1 - 32

characters

[Transmission interval]
Select a transmission interval for the alarm image FTP
transmission from the following.
0.1 fps/0.2 fps/0.33 fps/0.5 fps/1 fps
Default: 1 fps

[Number of images]
Select the number of images to be transmitted from the
following.
10 pics/20 pics/ 30 pics/50 pics/100 pics/200 pics/
300 pics/500 pics/1000 pics/2000 pics/3000 pics/
5000 pics
Default: 100 pics

[Recording duration]
Approximate time to be taken to save the set "number of
images" with the set "transmission interval" will be dis-
played.

[Image capture size]
Select "QVGA" or "VGA" for the image capture size of
images to be transmitted to the FTP server or of an
image to be attached to the alarm mail.
Default: VGA

Advertising