Polycom SpectraLink 8000 User Manual

Page 17

Advertising
background image

Installing the SpectraLink 8000 SVP Server

PN: 1725-36032-001_G.doc

17

2. Insert the #8 3/4-inch screws in the pilot holes and tighten,

leaving a 1/8-inch to 1/4-inch-gap from the wall.

Grounding Instructions



Safety

Warning

The metal chassis of this unit may contain leakage currents (i.e.,
"touch" current) which is cumulative when multiple units are
connected together to form a system. To prevent the summation of
leakage currents from being present on exposed metal surfaces, the
following installation procedure must be followed.

All system units must be grounded to a protective earth by means of
the grounding stud located on the rear panel. Refer to the illustration
below for recommended continuity connection.

No more than 15 units may be grounded through one connection to
the protective earth ground. Systems involving more than 15 units
must be broken up into groups of 15 or fewer units with each group
provided with an independent protective earthing conductor.

Connect SVP Server to LAN

Using a Cat. 5 cable, connect the

NETWORK

port on the SVP Server to

the connecting port on the Ethernet switch.

Connect power

1. Once the units have been properly grounded, connect the power

plug from the AC adapter to the jack labeled

PWR

on the SVP

Server.