E. THE SHAFT SEAL.

1.

The Shaft Seal consists primarily of two parts, a rotating member and a ceramic seal.

2.

The pump requires little or no service other than reasonable care, however, a Shaft Seal may occasionally become damaged
and must be replaced.

CAUTION

The polished and lapped faces of the seal could be damaged if not handled with care.

CAUTION

In mild climate area, when temporary freezing conditions may occur, run your filtering equipment all night to prevent

freezing.

SECTION II. TROUBLESHOOTING.

A. FAILURE TO PUMP.

1.

Pump will not prime - too much air. - Remedy:

a.

Check suction piping and valve glands on any suction gate valves.

b.

Secure lid on pump strainer pot and make sure lid gasket is in place.

c.

Check water level to make sure skimmer is not drawing air.

2.

Pump will not prime--not enough water. - Remedy:

a.

Make sure suction lines, pump strainer, and pump

volute are full of water.

b.

Make sure valve on suction line is working and

open, (some systems do not have valves).

c.

Check water level to make sure water is available

through skimmer.

3.

Pump strainer clogged. - Remedy:

a.

Clean pump strainer pot.

4.

Pump strainer gasket defective. - Remedy:

a.

Replace gasket.

B. REDUCED CAPACITY AND/OR HEAD.

1.

Air pockets or leaks in suction line. - Remedy:

a.

See item A.1. of this section, above.

2.

Clogged impeller. Remedy:

a.

Turn off electrical power to the pump.

b.

Remove the clamp that holds the volute to the seal

plate.

c.

Slide the motor and seal plate away from the

volute.

d.

Clean debris from impeller. If debris cannot be

removed, complete the following steps.

(1)

Remove left hand thread anti-spin bolt and
O-ring.

(2)

Remove, clean and reinstall impeller.

(3)

Reinstall anti-spin bolt and O-ring.

e.

Reinstall weir-ring, diffuser, and O-ring.

f.

Reinstall motor and seal plate into volute aligning

with keyway at top of volute.

g.

Reinstall clamp around seal plate and volute and

tighten securely.

3.

Pump strainer clogged. - Remedy:

a.

Clean suction trap.

0

10

20

30

40

50

60

70

80

90

100 110 120 130 140 150

0

10

20

30

40

50

60

70

80

90

100

110

FLOW IN GPM

TO

TA

L

DY

NA

M

IC H

E

A

D

IN

F

E

E

T

O

F

H

2

O

UF Performance Curves

NSF Listed Pumps

F

E

D

C

B

A

0

10

20

30

40

50

60

70

80

90 100 110 120 130 140 150 160 170 180

5

10

15

20

25

30

35

40

45

50

55

60

65

70