Paradyne Jetstream CPX-1000 User Manual
Page 107

February 2003
4-7
1000-A2-GN22-00
4. Troubleshooting
2.
Refer to
when troubleshooting the CP module.
3.
Refer to
when troubleshooting the MP module.
4.
Refer to
when troubleshooting the TDM T1
module.
5.
Refer to
when troubleshooting the ATM module.
6.
Refer to
when troubleshooting the LAN port.
Voice/Data Interruption
Do not press the
RST
button on the CP module. Doing so
resets the CPX shelf and interrupts all calls.
Table 4–4. CP Module Troubleshooting
Symptom
Probable Causes
Corrective Action
PWR
indicator is off.
CPX is not powered up.
Verify CPX is receiving –48 Vdc
from plant battery.
CP module did not
initialize properly upon
system power-up.
Turn CPX rear circuit breaker off,
then on again to cycle power and
reinitialize.
CP module is faulty.
Replace module (
).