Paradyne Jetstream CPX-1000 User Manual
Page 154

D. Specifications
1000-A2-GN22-00
D-6
February 2003
ATM Connection OC-3 Optical
Physical interface
Short-haul, single- or multi-mode, fiber optic (OC-3) cable
Max. span length: 5000 ft
Termination
Standard (SC) or Fusion Coupler (FC) connector plugs
Xmt power
MMF:
−19 to −14 dBm; SMF: −15 to −8 dBm
Rcv power
MMF:
−44.5 dBm to −8.0 dBm; SMF:−34 to −8 dBm
Wave length
1270–1380 nm
Logical interface
UNI
Max. span length
5000 ft.
Ethernet LAN
Physical interface
CAT-5 or equivalent cable for 10Base-T or 100Base-T
Termination
RJ-45 plug
Alarm Output Connection
Wiring requirement
22 AWG
Telco alarm signaling
Form-A solid-state closure Critical, Major, and Minor Alarm
with individual returns
Rated resistive load
20
Ω (typ) @ 50 mA
5
Ω (typ) @ 100 mA
Operating voltage
100 VDC/VAC (350 VDC or peak ac for 100 ms transients)
Continuous load
250 mA dc, 150 mA ac
Minimum load
10
µA at 10 mVDC
Table D–4. CPX-1000 Electronic Specifications (Continued)
Parameter
Specification