D. Specifications
Table D–5. CPX-1000 Operating Specifications
Parameter
Specification
Reference
Shock (Category A)
Packaged
Unpacked
450 mm (18 in.) drop height
25 mm (1 in.) drop height
GR-63-CORE, R4-41
GR-63-CORE, R4-43
Earthquake
Zone 4
GR-63-CORE, 4.4.1, R4-44
to O4-55
Vibration - Office
0.1g @ 5 to 100 Hz with 0.1 Octave/min.
GR-63-CORE, R4-56, R4-57
In Transit
3 axis, Curve 1
GR-63-CORE, R4-58
Maximum BTU
1720 BTU/hour
Heat dissipation
(forced air)
300W/m sq., per meter of frame height
used
38
°C (86°F) max. aisle-facing surface @
26
°C (80°F) ambient temperature
GR-63-CORE, O4-13
GR-63-CORE, O4-12,
O4-13
Fire resistance
All material meets ANSI
T1.307-1990 set 4.2 and UL94V-1 or better
GR-63-CORE, 4.2, R4-14 to
O4-40
Electromagnetic
Interference
GR-1089-CORE, Section
3.0
Table D–6. STS-1 Splitter Assembly Physical Specifications
Parameter
Specification
Dimensions:
3.5” high
× 17.2” wide (19” with mounting flanges) × 3” deep
Weight
2 lbs