Philips FMod-TCP BOX User Manual

Page 49

Advertising
background image

49 / 58

TCP TIMEOUT

Register Address Register

Name Function Read/Write

Control

0x14

TCPTIMEOUT

Timeout for TCP
connection

Read/Write

Register Size Register

structure Unit

1 Byte

Unsigned Int 8 bits

sec

Description:
The TCP timeout is a value (in seconds) after which the user will be
disconnected if the device has not been accessed in the meantime.

If the value is 0, the TCP timeout is deactivated. In this case however, if the
client crashes during connection, the communication will never be closed on
the module’s side! Because a maximum of 4 communications are allowed at
the same time on the module, one of them will be blocked. If the client
crashes four times, all of the 4 communications will be blocked and the
module will have to be reset!

The timeout for each TCP/IP connection is reloaded when there is traffic
through the port.

Default value:
30

Limitations:
Max value: 255

FMod-TCP User Manual v.2.8