[Intake Air Temp. - Remote Controller Setting Temp.] >
[Thermostat-OFF Temp. +0.5 °C]
Operated in corresponding frequency.

Frequency is decided after a completion of the starting
control (in 60 seconds).

When Room Temp. is below [Thermostat-OFF Temp.]
continuously for 3 minutes or more, it turns to Thermostat-
OFF operation.

When room temperature almost comes to Thermostat-OFF
Temp., the operation turns to the Minimum power & fan
speed: SSLo.

[Intake Air Temp. - Remote Controller Setting Temp.] >
[Thermostat-OFF Temp. +0.5 °C]
Operated in corresponding frequency.

Frequency is decided after a completion of starting control
(in 60 seconds).

When Room Temp. is below Thermostat-OFF Temp.
continuously for 3 minutes or more, it turns to Thermostat-
OFF operation.

When room temperature almost comes to Thermostat-OFF
Temp., the operation turns to the Maximum power.

Dry

Power

TE9DKE

TE12DKE

Intake Air Temp.

Difference (°C)

Maximum

2.7kW

4.0kW

Rated

2.5kW

3.6kW

Intermediate

~

~

Minimum

0.8kW

0.8kW

(-2.50)

OFF

Heating

Power

TE9DKE

TE12DKE

Intake Air Temp.

Difference (°C)

OFF

Minimum

0.8kW

0.8kW

Intermediate

~

~

Rated

3.5kW

4.5kW

(+1.00)

Maximum

4.6kW

6.2kW

9.3.2. Dry Operation

9.3.2.1. Thermostat Control

9.3.3. Heating Operation

9.3.3.1. Thermostat Control

22

CS-TE9DKE CU-TE9DKE / CS-TE12DKE CU-TE12DKE