Once abnormality has been detected during operation, the
unit will immediately stop its operation. (Timer LED blinks.)

Although timer LED goes off when power supply is turned
off, if the unit is operated under a breakdown condition, the
LED will light up again.

In operation after breakdown repair, error code is not
displayed. The last error code (abnormality) will be saved in
IC memory.

Timer LED Blinking in Abnormal Operation:
1. Automatically stops the operation.
2. Timer LED on display of the indoor unit blinks.
3. The LED will be off if the unit is turned off or the Error

RESET button on the remote controller is pressed.

To display memorized error (Protective operation)
status:
1. Turn the unit on.
2. Slide the remote controller cover down to appear the

operating buttons.

3. Press the CHECK button on the remote controller for

continuously 5 seconds or more to appear “--” on the
display.

4. Press the “TEMP”

or

button on the remote

controller to appear “H00” on the display. Signal is
transmitted to the main unit.

5. Press the “TEMP”

button (When

button is

pressed, the display goes back.) repeatedly and slowly
until Beep sound (about 5 seconds intermittently) is
heard from main unit.

6. Then, displayed error code matches to the error code

saved in unit memory. The power LED on the main unit
also lights up.
Mote:

When

the

CHECK

button

is

pressed

continuously for 5 seconds again, or when no
operation continues for 30 seconds, or when the
RESET button on remote controller is pressed with
a pointed object, the display is cancelled.

To clear memorized error (Protective operation) status
after repair:
1. Press the AUTO button in main unit continuously for 5

seconds or more and release it. (Test run / Pump down
operation: Beep sound)

2. Press the CHECK button on remote controller for about

1 second to transmit signal to main unit. A beep sound
is heard from main unit and the data is cleared.

Temporary

Operation

(Depending

on

breakdown

status)
1. Press the ON/OFF button after selecting Cooling or

Heating operation. (Receiving Beep sound is heard and
the TIMER LED blinks.)

2. The unit can temporarily be used until repaired.

Error Code

Operation

Temporary items

H23

Cooling

Emergency Operation
with limited power

H27, H28

Cooling, Heating

13.3. BREAKDOWN SELF DIAGNOSIS FUNCTION

13.3.1. Self Diagnosis Function (Three Digits Alphanumeric Code)

64

CS-TE9DKE CU-TE9DKE / CS-TE12DKE CU-TE12DKE

Advertising