Example 2

Map E1 Port 2 received, timeslots 1-32 to H.110 Port 1 timeslots 65-96.

Map E1 Port 2 transmitted, timeslots 1-32 from H.110 Port 1 timeslots 97-128.

Solution:

1. Under E1 Number, select port2(2) from the drop-down menu (see

figure 50

).

2. Under E1 Slots, enter 1-32 in the text box.

3. For toH110(5), under H.110 Number, select port1(1) from the drop-down menu.

4. For toH110(5), under H.110 slots, enter 65-96 in the text box.

5. For fromH110(5), under H.110 Number, select port1(1) from the drop-down menu.

6. For fromH110(5), under H.110 slots, enter 97-128 in the text box.

Figure 50. Define a Mapping table for example 2

7. Click the

Define

button.

8. Verify your new mapping appears in the Defined Mappings table (see

figure 51

).

Figure 51. Defined Mappings table for example 2

9. Examine the new mapping to verify that it was entered and recorded correctly.

You have completed the configuration for example 2.