Patton electronic 6511RC User Manual

Page 70

Advertising
background image

3 • Configuring the Matrix Switch for operation

Model 6511RC User Manual

70

Using a browser to complete Model 6511RC configuration

Figure 55. E1 port numbers located within the STM-1 frame structure

5. The first three parameters in the Define a Mapping section (see

figure 54

on page 69) specify an E1 signal

stream within the STM-1 link. The STM-1 link contains either three TUG-3s or three AU-3s (see

figure 55

). In the Define a Mapping section, the first parameter name will vary depending on the mapping

path you selected on the SDH configuration page. If you selected au3Mapper(0) then Au-3 will be dis-
played. If you selected au4Mapper(1) then Tug-3 will be displayed. To define the value of the first map-
ping parameter, select from the drop-down menu the AU-3 or TUG-3 number that contains the E1 you
wish to map. The options for the value of AU-3 are:

– au3-1(1)

– au3-2(2)

– au3-3(3)

The options for the value of TUG-3 are:

– tug3-1(1)

– tug3-2(2)

– tug3-3(3)

6. Each AU-4 or TUG-3 contains seven TUG-2s. To define the value of the TUG-2 parameter, select from

the drop-down menu the TUG-2 number that contains the E1 you wish to map. The options for the value
of TUG-2 are:

– tug2-1(1)

– tug2-2(2)

– tug2-3(3)

– tug2-4(4)

– tug2-5(5)

Advertising