Indoor Pan/Tilt Head AW-PH400

14

Installation

(Be sure to ask your dealer to install the unit.)

$

Setting the mounting direction switch

Set the switch as follows when the unit is to be installed on the ceiling.
(This switch was set to the stand-alone installation position at the factory.)

1

Remove the four screws, and gently remove the pedestal connector panel.

2

Set switch S1 on the PCB inside the pan/tilt head as follows.

For stand-alone installation:

Set S1 to the rear position (T). (Factory setting)

For installation on the ceiling:

Set S1 to the front position (H).

3

Upon completion of the setting, return the pedestal connector panel to its original position, and attach it using the screws.
(Take care not to pinch or disconnect the wires.)

Be absolutely sure to turn off the power before changing the position of this switch.

Pedestal connector panel

S1

Front position (H)
for installation on

the ceiling

Rear position (T)

for stand-alone

installation

S1

S2