4.3.2 CONNECTING THE LINE INTERFACE

The Model IM2RC/F is to be used with Patton function card access

products (i.e. 1045RC, 1092RC, 1092ARC, 2500RC) that support
64k/128k synchronous data rates. There are two essential
requirements for connecting the line interface on Model IM2RC/F:

1. These units work in

pairs

. Both units at the end of the twisted

pair must have the proper 2-Wire/4-Wire setting. For
instance, if you are operating in 2-Wire mode, both units must
be in the 2-Wire setting. Similarly, if you are operating in 4-
Wire mode, both units must be in the 4-Wire setting.

NOTE:

Currently only the 1092 and 1092A families support 2-Wire
Mode.

2. To function properly, the Model IM2RC/F needs one or two

twisted

pairs of metallic wire. The twisted pairs must be

unconditioned

, dry, metallic wire, between 19 (.9mm) and 26

AWG (.4mm) (Appendix B describes cable requirements) .
Standard dial-up telephone circuits, or leased circuits that run
through signal equalization equipment, or standard, flat
modular telephone type cable, are

not acceptable

. Figure 7,

below, shows the pin/signal relationships of the Line Interface
Port.

12

4.3 MAKING INTERFACE CONNECTIONS

The Model IM2RC/F is designed to provide access to a 64 kbps

co-directional G.703 PCM network. Figure 5 shows the position of the
G.703 interface and the line interface of the IM2RC/F. This section
describes how to connect the G.703 interface and the line interface.

4.3.1 CONNECTING TO A G.703 PCM NETWORK CHANNEL

The 120 Ohm RJ-45 port on a Model IM2RC/F is pre-wired for

direct connection to the G.703 PCM network. Connect the RJ-45 jack
provided by your digital service carrier to the 120 Ohm G.703 interface
on the Model IM2RC/F using a

straight through

twisted pair cable

between 19 and 26 AWG (0.4mm to .9mm, inversely). To be sure you
have the right wiring, refer to Figure 6, below.

11

120 Ohm RJ-45

G.703 Interface

RJ-45 Line Interface

Figure 5:

Model IM2RC/F Interface Ports

Figure 6:

120 Ohm RJ-45 G.703 Interface

1 (RX+)
2 (RX-)
3 (N/C)
4 (TX-)
5 (TX+)
6 (N/C)
7 (N/C)
8 (N/C)

1
2
3
4
5
6
7
8

Notice!

The G.703 line surge protection on this unit was

installed for circuit protection only. By no means does this
include the preservation of signal quality during a large surge.

Figure 7:

RJ-45 Line Interface

1 (4-Wire RX+)
2 (4-Wire RX-)
3 (no connection)
4 (2-Wire TIP)/(4-Wire TX+)
5 (2-Wire RING)/(4-Wire TX-)
6 (no connection)
7 (no connection)
8 (no connection)

1
2
3
4
5
6
7
8