Notice – Patton electronic IM2RC/F User Manual

Page 8

Advertising
background image

5.0 OPERATION

Once the Model IM2RC/F is installed and configured, it should

operate transparently. This sections describes a typical application
and general operating instructions.

5.1 TYPICAL APPLICATION

The Model IM2RC/F allows a remotely connected LAN or high

speed application to connect to the 64k/G.703 (PCM) network through
a pair of Patton baseband modems. Figure 8 (below) shows a typical
application of the IM2RC/F.

5.2 OPERATING INSTRUCTIONS

In order to operate, the Model IM2RC/F must be installed in the

rear of a Patton 16 port rack or a 2, 4, or 8 port ClusterBox™ chassis.
A front function card, such as a baseband modem, CSU/DSU, or HDSL
modem meets the IM2RC/F rear card in the mid-plane of the chassis.
The IM2RC/F also requires a G.703 connection to the 64 kbps co-
directional PCM network and a line connection to a remote Patton
transmssion device. After applying power, the function card and
IM2RC/F operate transparently according to the applied settings
(Please refer to the function card manual for further details).

14

4.3.3 Two-Wire and Four-Wire Cable Connection Via RJ-45

1. The Line Interface Port on the Model IM2RC/F’s twisted pair

interface is polarity insensitive and is wired for a two-wire
interface.

2.

Proper

2-Wire Pairing

between the two modems is as follows:

SIGNAL

PIN#

PIN#

SIGNAL

TIP 4--------------------------------------------- 4 TIP
RING 5--------------------------------------------- 5 RING

3.

Proper

4-Wire Pairing

between the two modems is as follows:

SIGNAL

PIN#

PIN#

SIGNAL

Tx 4--------------------------------------------- 3 Rx
Tx 5--------------------------------------------- 6 Rx

Rx 3--------------------------------------------- 4 Tx
Rx 6--------------------------------------------- 5 Tx

NOTE:

The pin designations shown above are to be used when

connecting to another IM2RC/F or other similarly pinned line
interface on a Patton rear card. Please review the appropriate
function card user manual or stand-alone product user manual to
determine the correct pin assignments.

13

Notice!

Any G.703 or line interface cable connected to the

Model IM2RC/F must be shielded cable, and the outer shield
must be 360 degree bonded–at both ends–to a metal or
metalized backshell.

Figure 8:

IM2RC/F Typical Application

LAN

Router

G.703

PCM

Network

Rack-Mounted

Baseband Modem, CSU/DSU,

HDSL Modem, etc. with

IM2RC Rear Card

Remote Baseband

Modem, CSU/DSU, HDSL

Modem, etc.

Advertising