79 rmon alarm <index> owner, 80 rmon alarm <index> rising_eventindex, 81 rmon alarm <index> rising_threshold – Planet Technology IDL-2402 User Manual
Page 267

<number>
RMON alarm falling threshold
Valid values: 0~4294967295
Default value: -
Type: Mandatory
5.4.79 rmon alarm <index> owner
Description RMON alarm owner
Syntax rmon alarm <index> owner <string>
Parameter
Name
Description
<string> Owner
name.
Valid values: (max 31 characters)
Default value: -
Type: Mandatory
5.4.80 rmon alarm <index> rising_eventindex
Description Set RMON alarm rising event index
Syntax rmon alarm <index> rising_eventindex <number>
Parameter
Name
Description
<index>
RMON alarm entry index
Valid values: 1~64
Default value: -
Type: Mandatory
<number>
RMON alarm rising event index
Valid values: 1~128
Default value: -
Type: Mandatory
5.4.81 rmon alarm <index> rising_threshold
Description Set RMON alarm rising threshold
Syntax rmon alarm <index> rising_threshold <number>
Parameter
Name
Description
<index>
RMON alarm entry index
Valid values: 1~64
- 267 -