5.4.119 tcm yellow
Description
Set TCM yellow color value
Syntax
tcm yellow <number>
Parameter
Name
Description
<number>
TCM yellow color value
Valid values: 0 ~ 7 for VLAN priority color
field;
0 ~ 63 for DSCP color field
Default value: 3
Type: Mandatory
5.4.120 temperature threshold
Description
Shelf temperature threshold
Syntax
temperature threshold {up | down | fan} <number>
Parameter
Name
Description
<number>
Temperature threshold value.
Valid values: up: -55~85
Down: -55~85
fan: -40~15
Default value: up: 65
down: 65
fan: -40
Type: Mandatory
5.4.121 temperature shelf time
Description
Shelf time
Syntax
temperature shelf time {up | down} <number>
Parameter
Name
Description
<number>
Shelf time value.
Valid values: 1~255
Default value: 10
Type: Mandatory