19 spectrum profile configure mode commands, 1 aggregate, 2 bands <index> {start | stop – Planet Technology IDL-2402 User Manual
Page 355: 3 bands <index> mask

- 355 -
5.19 Spectrum Profile Configure Mode Commands
The commands in this section can be executed only in the Spectrum Profile execution
mode.
5.19.1 aggregate
Description
Set downstream/upstream aggregate power level
Syntax
aggregate {ds | us} max powerlevel <number>
Parameter
Name
Description
<number>
Power level (tenth dBm).
Valid values: 0~25.5 step 0.1
Default value: -
Type: Mandatory
5.19.2 bands <index> {start | stop}
Description
Set RF bands
Syntax
bands <index> {start | stop} <value>
Parameter
Name
Description
index
Bands array index.
Valid values: 0-7
Default value: -
Type: Mandatory
value
Set start / stop frequency (kHz).
Valid values: 0-12000
Default value: -
Type: Mandatory
5.19.3 bands <index> mask
Description
Set bands mask
Syntax
bands <index> mask <value>