Pentair Pressure Side Pool Cleaner Legend II User Manual

Page 10

Advertising
background image

LEGEND® II INSTALLATION MANUAL

3. Checking RPM - (cont.)

1. Clean the Screen located inside the Wall Fitting.

A small amount of debris will significantly affect
the performance of the cleaner.

2. Clean the skimmer basket, pump basket and pool

filter.

3. If an adjustable Gate (3-way) Valve has been

installed, adjust the valve to increase water flow
to the Legend

®

II.

4. If the RPM is more than 32, at the Wall Fitting,

unscrew the Pressure Relief Valve slowly until
the RPM falls between 25-32. Again, if an
adjustable gate (3-way) valve has been installed,
adjust the gate valve to decrease water flow to
the Legend

®

II.

5. If you continue to have problems with either the

water flow or obtaining the specified water
pressure to operate the Legend

®

II, call your

Professional Pool Dealer.

If you have any additional questions, please

contact Pentair Water Pool and Spa, Inc.,

Technical Support Department at:

1-800-831-7133, Monday through Friday.

6

Advertising