Optional Coaxial/Twinaxial Interface

Page C-2

In the DSC/DSE type LU3 mode, both formatted and unformatted data streams are supported.

Interface diagnostics are available at the end of this appendix in the section titled
“Coaxial/Twinaxial Interface Diagnostics”.

CX/TX Interface.

Option Switches When Configured for Coaxial Operation

The dipswitches as shown above have the following meanings when the interface is
configured for coaxial operation. An asterisk (*) indicates the factory default setting.

Switch/Position

Function

SW1-1 OFF*

Select IBM 3287 Emulation.

SW1-1 ON

Select IBM 3262 Emulation.

SW1-2 OFF*

Reserved for future use.

SW1-3 OFF*

Reserved for factory use.

SW1-4 OFF*

Reserved for factory use.

SW1-5 OFF*

Set default Maximum Print Position to 132
columns.

SW1-5 ON

Set default Maximum Print Position to none.

SW1-6 OFF*

Set default Maximum Print Line to none.

SW1-6 ON

Set default Maximum Print Line to 66 lines.

SW1-7 SW1-8

Parallel multiplexer timeout.

OFF*

OFF*

Short (15 seconds)

ON

OFF

Medium.