Operations Manual, HPA2, Compact Outdoor SSPA

The Compact Outdoor SSPA responds with the following Response String:

Byte Position Byte Value (Hex) Description

1

AA

Frame Sync Byte 1

2

55

Frame Sync Byte 2

3

A

Destination Address of PC Request originator

4

5

Source Address of SSPA sending Response String

5

0

Protocol Version Compatibility Field must always be 0

6

6F

Echo of the originator Request ID byte

7

3

Command “Get response” designator

8

3

Data tag “3”, Systems Conditions access

9

0

Error status; 0 = no errors

10

12

Data length is 18 bytes

11

47

Tempcomp attenuator DAC value, Low Byte

12

2

Tempcomp attenuator DAC value, High Byte; DAC value = 583

13

1C

SSPA internal core temperature, Low Byte

14

0

SSPA internal core temperature, High Byte; Temp. = 28 °C

15

0

SSPA Fault Status, Low Byte (see Table 10-9, data address 3)

16

80

SSPA Fault Status, High Byte (see Table 10-9, data address 3)

17

C8

SSPA Attenuation Level, Low Byte

18

0

SSPA Attenuation Level, High Byte; Attenuation = 200, or 20.0 dB

19

82

Forward RF Output, Low Byte

20

1

Forward RF Output, High Byte; Forward RF = 386, or 38.6 dB

21

B6

SSPA DC Current, Low Byte

22

2

SSPA DC Current, High Byte; DC Current = 694, or 69.4 Amps

23

67

SSPA Regulator DC Voltage, Low Byte

24

0

SSPA Regulator DC Voltage, High Byte; Voltage = 103, or 10.3 Volts

25

95

SSPA Power Supply Voltage, Low Byte

26

0

SSPA Power Supply Voltage, High Byte; Voltage = 149, or 14.9 Volts

27

D3

SSPA Gate Drive Voltage, Low Byte

28

FF

SSPA Gate Drive Voltage, High Byte; Voltage = -45, or -4.5 Volts

29 4C

Arithmetic

checksum of bytes 3 through 28