Adjustment(precise adjustment), Daf adjustment – Panasonic CT-36SX31E User Manual

Page 15

Advertising
background image

- 15 -

Y

H

Adjustment (VR2 for Vertical dynamic

convergence)
1.

Apply a crosshatch pattern.

2.

Adjust contrast and brightness customer controls
to obtain a correct picture.

3.

With a driver Adjust VR2 (located in deflection yoke
board Fig. 19) to obtain a proper corvergence at
left and right side of the screen. (See Fig. 14)

X

V

Adjustment(precise adjustment)

1.

Apply a crosshatch pattern.

2.

Adjust contrast and brightness customer controls
to obtain a correct picture.

3.

With a driver adjust the coil located in deflection
yoke board to obtain a proper convergence
horizontally.

Note: Apply a red pattern and confirm purity, if purity

is poor, repeat purity adjustments.

Permalloy Convergence Corrector Strip
(Part No. 0FMK014ZZ)

This strip is used in some sets to match the yoke and
CRT for optimum convergence. If the yoke or CRT is
replaced, the strip may not be required.
First converge the set without the strip and observe
the corners.

If correction is needed:

1.

Place strip between CRT and yoke, in quadrant
needing correction. Slowly move it around for
desired results.

2.

Press adhesive tightly to the CRT and secure
with tape.

DAF Adjustment

Preparation:
1.

Apply a crosshatch pattern.

2.

Set user controls, bright to center and picture to
max.

3.

Connect a frequency counter to TPD10.

Procedure:
1.

Connect channel one of the oscilloscope with 10x1
probe to TPP33.

2.

Connect channel two of the oscilloscope with 10x1
probe to CRT HEATER (L-Board).

3.

Adjust R1581 so that frequency counter reads
15.7kHz±100Hz.

4.

Adjust R1577 so that signal on TPP33 is on phase
with CRT HEATER (L-Board) pin. (see Fig. 16)

G B&R G B&R

G B&R G B&R

Figure 14. VR2 Adjustment (Y

H

)

G

B&R

G

B&R

G

B&R

G

B&R

Figure 15. X

V

Adjustment

TPP33

HEATER
PIN

Figure 16. DAF Adjustment

Advertising
This manual is related to the following products: