Panasonic CT-36SX31E User Manual

Page 28

Advertising
background image

- 28 -

Procedure:
1.

Connect the oscilloscope to TPY1.

2.

Apply a color bar signal in main and PIP (PIP on).

3.

In the Serviceman Mode for making electronic
adjustments, select the DAC adjustment (P03) for
PIP Sub-Subcontrast so that child (PIP) level is
90% of parent (MAIN) signal (See Fig. 29)

Color Temperature Adjustment
(B/W Tracking)

Serviceman DAC Adjust.
(C00) (C01) (C02) (C04) (C05)
Minor Touch-Up Method

OBSERVE low and high brightness areas of a B/W
picture for proper tracking. Adjust only as required for
“good gray scale and warm highlights”.
1.

LOW LIGHT areas – In Serviceman Mode for
making electronic adjustments, select Cutoff (C00)
RED, (C01) GRN, (C02) BLU and adjust the
picture for gray.

2.

HIGH LIGHT areas – In Serviceman Mode for
making electronic adjustments, select Drive (C04)
GRN, (C05) BLU and adjust the picture for warm
whites.

Complete Adjustment

Preparation:

1.

Turn the Receiver “ON” and allow 10 minutes
warm up at high brightness.

2.

Apply a color bar signal with color “OFF”.

3.

Turn the SCREEN control (part of FBT T551) fully
counterclockwise.

Procedure:

Preset the following Serviceman DACs for best results:

• C0 . . . . . . . . . . . . . . 128
• C1 . . . . . . . . . . . . . . 128
• C2 . . . . . . . . . . . . . . 128
• C4 . . . . . . . . . . . . . . . 64
• C5 . . . . . . . . . . . . . . . 64

1.

Connect the oscilloscope to TP37 (L-Board).

2.

In Serviceman Mode for making electronic
adjustment, select the Sub-Bright DAC (B02).

3.

Press the R-Tune key on the remote.

4.

Observe the oscilloscope waveform at Horizontal
rate and adjust the Serviceman Mode Sub-Bright
DAC (B02) level until a scanning period of
2.3±0.05V above DC ground is measured, as
indicated in Fig. 30.

5.

Press the R-Tune key on the remote.

6.

Connect the scope to RED Cathode (KR) on the
CRT-Board.

7.

In the Serviceman Mode for making electronic
adjustments, select the RED CUTOFF DAC (C00).

8.

Press the R-Tune key on the remote.

9.

View scope trace at Horizontal rate and adjust the
Serviceman Mode DAC (C00) level until a
scanning period of 170±2V above DC ground is
measured, as indicated in Fig. 31.

10. Press the R-Tune key on the remote.

11. Write the same C00 data to C01 and C02.

12. Press the R-Tune key on the remote.

13. Turn the Screen Control (part of FBT) slowly

clockwise until a slightly color horizontal line
appears.

14. Adjust DAC C01 and C02 until the horizontal line

becomes white.

15. Press the R-Tune key on the Remote

16. In the Serviceman Mode for making electronic

adjustments select the DAC DRIVE adjustments
(C04) GRN, (C05) BLUE and adjust for warm white
in a white color bar pattern.

17. Apply a monoscope pattern and check for a good

picture.

18. EXIT the Serviceman Mode.

A

Ax0.9

Figure 29. Waveform

0V DC

Figure 30. TP35 Waveform

2.3±0.05V DC

Figure 31. KR Waveform

170±2V DC

0V DC

(Ground)

Advertising