Service adjustments (electronic controls, cont.), Service adjustments (mechanical controls) – Panasonic CT-36SX31E User Manual

Page 31

Advertising
background image

- 31 -

Service Adjustments (Electronic Controls, cont.)

Clock Adjustment (S07)

Preparation:

Connect the frequency counter to TPS1 (IC001

pin-13) and cold ground (

).

Note: Frequency Counter probe capacitance should

be 8pF or less.

Procedure:
1.

Measure TPS1 (IC001 pin 13) for the frequency of
the waveform and record the reading.

Note: Pin 13 measurement must have at least four

digits of resolution following the decimal point.
Example: 000.0000

2.

Place the Receiver into Serviceman Mode for
making electronic adjustment, select the Clock
Adjustment DAC (S07).

3.

Calculate and set S07 based on the
following formula:

Note: Pin 13 measurement will not change

regardless of the value stored in S07.

Service Adjustments (Mechanical Controls)

Focus (part of T551)

This adjustment is to make the picture clear
Preparation:
Connect a Signal generator and select a dot pattern.

Procedure:
Adjust the FOCUS controls to obtain the sharpest and
clearest dot pattern.
a. Adjust VF1 to minimize width on vertical lines on
corners.
b. Adjust VF2 to minimize width on horizontal lines

on corners.

S07

128

873.90625

pin13 Hz

[

]

{

}

968

+

=

Figure 38. Set Turned ON

S07

128

218.47656

pin13 Hz

[

]

{

}

3873

+

=

Figure 39. Set Turned OFF