Actuator Lighting Module (Not Shown)

The actuator lighting module is also located on the power base. The actuator lighting module provides a control and power interface

between the power module, the lights, and/or the power seat actuator.

Sleep Mode

Your Remote Plus controller has a sleep mode feature. Sleep mode is a built-in circuit that automatically shuts off the main

power if the joystick is not moved in any direction for a period of time. The battery condition meter lights on the keypad

indicate sleep mode by blinking once every 25 seconds. To restore power and continue, push the on/off key twice.

Trouble Codes

In addition to indicating the current state of battery charge, the battery condition meter can also indicate possible problems with

your power chair. The battery condition meter has ten lights. The lights provide information by the number of lights that are

flashing. If any of the meter lights are flashing rapidly, the controller may be indicating a fault. For instance, if the first light is

flashing rapidly, the battery voltage is nearly depleted. The following is a list of the possible errors signified by the rapidly

flashing meter. When you get a trouble code, contact your authorized Pride provider.

FLASHING LIGHTS

DIAGNOSIS

SOLUTION

10

High Battery Voltage

Check batteries.

9

Solenoid Brake Fault

Check motor/brake wiring.

8

Possible Controller Fault

See authorized Pride provider.

7

Possible Joystick Fault

See authorized Pride provider.

6

Inhibit Active

Unplug charger. Check connections.

5

Right Motor Wiring Fault

Check right motor wiring.

4

Right Motor Disconnected

Check right motor wiring.

3

Left Motor Wiring Fault

Check left motor wiring.

2

Left Motor Disconnected

Check left motor wiring.

1

Low Battery Voltage

Check batteries/battery wiring.