-6-

• Switch off all the devices before making any connec-

tion.

• Use the Pan/tilt Head AW-PH300.
• Connect the DC 15V OUT Terminals [+] and [–] on this

adapter to the DC 15V IN Terminals [+] and [–] on the
Pan/tilt Head (AW-PH300) respectively with cables (to
be locally purchased) with a nominal cross section of
1.25 mm

2

or more that meets the UL specifications.

The maximum allowable cable length between the
adapter and pan/tilt head is 30 meters.
Applicable (usable) wire

Solid wire:

ø1.29 (AWG 16)

Stranded wire:

1.25mm

2

(AWG 16)

Strand diameter ø0.18 or more

Standard bare end length:

11 mm

• To switch on and off the halogen lamp from the control

panel, connect the LAMP CONTROL Input Terminals
[C] and [S] to the LAMP CONTROL Output Terminals
[C] and [S] on the pan/tilt head respectively with cables
(to be locally purchased) with a nominal cross section
of 0.3 mm

2

or more that meets the UL specifications.

The maximum allowable cable length is 30 meters.
Locally purchase an AC plug conversion cable that
matches the AC plug for the halogen lamp to be used,
and connect a halogen lamp of 250 W to 500 W to the
lamp AC outlet. If a halogen lamp of less than 250 W is
connected, the LAMP Indicator on the control panel
may flash to indicate a burnt bulb even though the
lamp is normal.

CONNECTION

Applicable wire

Solid wire:

ø1.29 (AWG 16)

Stranded wire:

1.25 mm(AWG16)

2

Usable wire range

Solid wire:

ø0.64 to 1.29 (AWG 22 to 16)

Stranded wire:

0.3 mm

2

to 1.25 mm

2

(AWG 22 to 16)
Strand diameter ø0.18 or more

Standard bare end length:

11 mm

• To control the option switch terminal to short or open

from the control panel, connect the OPTION SW CON-
TROL IN Terminal [OP] on the adapter to the OP
Output Terminal on the pan/tilt head with a cable (to be
locally purchased) with a nominal cross section of 0.3
mm

2

or more that meets the UL specifications. The

maximum capacity of the option switch terminal is
120V 1A (AC/DC).
Applicable wire

Solid wire:

ø1.02 (AWG 18)

Stranded wire:

0.75 mm

2

Usable wire range

Solid wire:

ø0.64 to 1.02 (AWG 22 to 18)

Stranded wire:

0.3 mm

2

to 0.75 mm

2

(AWG 22 to 20)
Strand diameter ø0.18 or more

Standard bare end length:

10 mm

• For details on the connection, refer to the Operating

Instructions.