Safety preca utions, Air conditioner inst alla tion – Panasonic CW-XC122VU User Manual

Page 2

Advertising
background image

Please observe these following safety precautions when using
your air conditioner.
Failure or negligence in observing these safety precautions

could cause fire, electrical shock or personal injury.

This symbol (with a white background)
denotes an action that is PROHIBITED.

1

SAFETY PRECA

UTIONS

These symbols (with a blue background) denote
actions that are COMPULSORY.

INSTALLATION PRECAUTIONS

OPERATION PRECAUTIONS

This sign warns of risk of death or serious injury.

• Do not modify the length of the power cord or use an extension cord.
• Do not touch or operate with wet hands. Do not modify or damage

the cord.

• Do not turn on the unit by inserting the power plug. Do not switch off

the unit by pulling out the power plug.

• Avoid an extended period of direct airflow.
• Do not insert sticks, fingers or other objects into the unit.
• Do not try to repair the unit yourself.

• Plug in properly before operating and use a specified power cord.
• If abnormal conditions (burnt smell, etc) occur, switch off and remove

the power plug.

WARNING

• Do not use the unit for other purposes, than its intended use.
• Do not remove the power plug by pulling the cord.
• Do not block the air intake and outlet vanes.
• Do not splash or direct water at the unit
• Do not expose the unit to direct sunlight during operation.
• Do not operate the unit without the air filter installed or when the front

intake grille has been removed.

• Do not place any objects on the unit.
• Do not operate any combustion equipment near the unit’s airflow area.

• Switch off the breaker and remove the power plug from the socket if

the unit will not be operated for a long period.

• Pay attention to any damages on the unit caused by extensive usage.
• Ventilate the room occasionally where the unit is installed.
• Remove the power plug when cleaning the unit.

CAUTION

2

AIR CONDITIONER INST

ALLA

TION

• Due to the weight of this product, we recommend that

you have a helper to assist in the installation. To avoid
injury, use the proper method of lifting. Avoid any sharp
edges.

• Make sure the window frame to be used can

properly support this product.

• This product must be installed in accordance with all local

codes and ordinances.

• Do not install the unit in places where inflammable gas,

fumes or soot may be generated.

POWER SUPPLY

• Operate your air conditioner from a stable 115 volt AC

supply.

• Plug into a separate 15 amp grounded outlet only.
• Use of extension cords

Avoid using extension cords. If there are no alternatives,
ensure that the cord is a UL listed 3-wire grounding type,
rated 125 volts with a minimum current-carrying rating of
15 amps, number 14 or heavier wire.

• Use a 15 amp time delay fuse or a circuit breaker.
• Do not switch off by unplugging the power plug while it is

operating. Press the OFF/ON pad to “OFF” before
unplugging.

This sign warns of injury or damage to property.

OPERATION PRECAUTIONS

Time Delay Fuse : 15 Amps
Rated Voltage : 115V

• Socket Type

• Line Cord Plug

INSTALLATION BOX CONTENTS

Sealer 50 g
(1.8 oz) (Putty)

Type A
screw

Window sash
sealing ribbon

Type C screws

Type B screws

Left side
expandable panel

Type A
screws

Type C screws

Top
angle

Window sash
foam seal

Right side
expandable
panel

Type A

Type B

Type C

(Qty 6)

(Qty 5)

(Qty 6)

SCREW FURNISHED

Wood

Machine

Tapping

Screw

Screw

Screw

SUGGESTED TOOL LIST

Medium sized
screwdriver (#2
Phillips)

Tape Measure

Pencil

Level

Knife or
Scissor

ACCESSORIES

NOTE
Check that none of the accessories are missing.

(6 pcs)
(XTN5D25A)

(5 pcs)
(CWH4580211)

(6 pcs)
(XTT4D10C)

SELECT THE BEST LOCATION

(Single or Double
hung window)

19–

3

/

16

inches

SIDE VIEW

Front grille

Window

12 inches

More than
4 inches

Type A screws

Type A screw

Top sealing
ribbon

Side
sealing
ribbon

Advertising