Model 4210 alarm/bits connector, Model 4210 alarm/bits, Connector – Paradyne IP DSLAM GranDSLAM 4200 User Manual
Page 56
Advertising

A. Connectors and Pin Assignments
A-4
January 2004
4200-A2-GN20-40
Model 4210 ALARM/BITS Connector
The alarm relay reports major alarms through the ALARM connector (top row of
contacts on the ALARM/BITS terminal block) on the front panel of the GranDSLAM
Model 4210. The BITS connector (bottom row of contacts, pins 1–3) is for future
use.
The alarm contacts are closed during normal operation. They open in response to
loss of power, hardware failure, or other alarm conditions. The maximum rated
load for the alarm relays is:
30 VDC: 1.0 Amp
60 VDC: 0.6 Amp
60 VAC: 0.6 Amp
Table A-4.
Model 4210 ALARM/BITS
Connector Pinouts
Signal
Direction
Pin
BITS Tip
In
1
BITS Ring
In
2
BITS Shield
Ground
3
Major Alarm
Out
4
Common
Out
5
Minor Alarm
Out
6
02-17340
3 2 1
6 5 4