Lamp select, English – 79, Special featur es lamp select – Panasonic PT-DZ12000E User Manual

Page 79: Press ▲▼ to select “lamp 1. select, Press ◄► to switch “lamp 2. select, Press enter. 3

Advertising
background image

ENGLISH – 79

Special Featur

es

Lamp select

This lets you switch the four light source lamps to one
of four brightnesses in accordance with the operating
conditions and purpose of use.

Press

▲▼ to select “LAMP

1.

SELECT”.

DIRECTION

LAMP SELECT

LAMP RELAY

HORIZONTAL

QUAD

OFF

Press

◄► to switch “LAMP

2.

SELECT”.

The setting will change as follows each time

•

◄► is pressed.

TRIPLE

QUAD

DUAL

L1

SINGLE

L2

L2/L3/L4

L3

L1/L3/L4

L4

L1/L2/L4

L1/L4

L1/L2/L3

L2/L3

“QUAD” :

•

The four lamps illuminate.

“L1” :

•

One lamp illuminates.

(Lamp unit 1 takes priority.)

“L2” :

•

One lamp illuminates.

(Lamp unit 2 takes priority.)

“L3” :

•

One lamp illuminates.

(Lamp unit 3 takes priority.)

“L4” :

•

One lamp illuminates.

(Lamp unit 4 takes priority.)

“L1/L4” :

•

Two lamps illuminate.

(Lamp unit 1 and 4 take priority.)

“L2/L3” :

•

Two lamps illuminate.

(Lamp unit 2 and 3 take priority.)

“L1/L2/L3” :

•

Three lamps illuminate.

(Lamp units 1, 2 and 3 take priority.)

“L1/L2/L4” :

•

Three lamps illuminate.

(Lamp units 1, 2 and 4 take priority.)

“L1/L3/L4” :

•

Three lamps illuminate.

(Lamp units 1, 3 and 4 take priority.)

“L2/L3/L4” :

•

Three lamps illuminate.

(Lamp units 2, 3 and 4 take priority.)

“SINGLE” :

•

One of the lamps illuminates.

(The lamp unit with the shortest operating time is
selected automatically.)

“DUAL” :

•

Two lamps illuminate.

(The lamp units with the shortest operating time
out of lamp units 1 and 4 or 2 and 3 are selected
automatically.)

“TRIPLE” :

•

Three lamps illuminate.

(The lamp unit with the shortest operating time is
selected automatically.)

Press ENTER.

3.

Note

For settings other than “QUAD”, any lamp which is

•

malfunctioning or which has a cumulative operating
time that exceeds 2 000 hours will be turned off
and the other lamps will be turned on. If “QUAD”
is selected, any lamp which is malfunctioning or
which has a cumulative operating time that exceeds
2 000 hours will be turned off and only the lamps
which have a cumulative operating time of less than
2 000 hours will be turned on. In addition, if the
cumulative operating times for all lamps exceed
2 000 hours, the projector will switch to standby
mode.

Lamp units which are not turned on should still be

•

installed to the projector.

When it is time to replace the lamp, the number of

•

the lamps that illuminate will be greater than the
specified number of lamps in order to prevent the
luminance from dropping.

The characters in the lamp selection menu

•

will become green when they are selected.
Furthermore, the characters may flash depending
on the condition of the lamps.
Yellow:

An error has occurred with the
illumination of one or more of the lamps

White: Unselected

item

Red:

Lamp where an illumination error has
occurred

Advertising