Component Replacement

The RMX 4000 is designed with ease of maintenance in mind. Most

components are swappable and are accessible directly via the front panel
or the rear panel.

The following components can be replaced when they are faulty:

CNTL 4000 Module, see "Replacing the CNTL 4000 Module” on

page

2-4

.

AC Power Supply Modules, see "Replacing an AC Power Supply

Module” on page

2-5

.

AC Power Entry Modules, see "Replacing an AC Power Entry Module

(PEM)” on page

2-6

.

DC Power Rail Modules, see "Replacing a DC Power Rail Module

(PRM)” on page

2-7

.

Fan drawer, see "Replacing the Fan Drawer” on page

2-9

.

Adding an Air Filter, see "Inserting an Air Filter (Optional) in the Fan

Drawer” on page

2-10

.

MPM+ card. This card is hot-swap enabled. See "Replacing a Faulty

MPM+ Card” on page

2-11

.

RTM ISDN card, see "Replacing a RTM ISDN Card” on page

2-14

.

RTM-IP 4000 card, see "Replacing the RTM-IP 4000” on page

2-16

.

RTM LAN card, see “Replacing the Fabric Switch Module (FSM 4000)”
on page

2-18

.

The MPM+, RTM ISDN, power supplies and Fan tray are Hot Swappable. The
Fan tray must be replaced immediately or the temperature spike in the RMX
shall initiate a shutdown. The RTM-IP 4000, RTM LAN, Fabric Switch Module
(FSM) 4000 and the CTNL 4000 are not Hot Swappable. System shutdown is
required when replacing the RTM-IP 4000, RTM LAN, FSM 4000 and the CTNL
4000.