Polycom RMX DOC2548A User Manual

Page 54

Advertising
background image

Chapter 2- Component Replacement

2-12

2

Power down the card by partially opening the ejector levers until the
blue HS LED on the card and the Control Unit start to flash.

3

The power off sequence for the interconnected MPM+ and RTM

ISDN cards are initiated as follows:
—

All participant connections on the card are disconnected.

—

A fault is generated on the system.

—

For each disconnected participant, a participant disconnection

event is written to the CDR with the disconnection cause

Disconnected by Operator.

—

New participant connections are blocked when the card is

removed.

—

If an RTM ISDN card is connected to the MPM+ card it is also

powered off and all ISDN and PSTN participants are

disconnected.

—

When an RTM ISDN card is removed, its resources are deducted

from the Resource Report.

—

A Log File entry is written indicating MPM+ card removal.

—

Port usage is re-calculated and the Port Gauges and Video/Voice

Port Configuration dialog box are updated.

4

When the blue HS LEDs on the MPM+, RTM ISDN and Control Unit

stop flashing and remain lit, unscrew the captive screws and move

the ejector levers to their fully open position and remove the MPM+

card.

Warning!
Once the removal sequence is initiated the process cannot be terminated and
the HS LED flashes.