PowerTec OMRG25204 User Manual

Page 118

Advertising
background image

Service as Required

OURGP11,000000D

–19–18OCT06–4/7

RG6264

–UN–03NOV97

Stanadyne Rotary Fuel Injection Pump

A—Fuel Return Line Connector

At Fuel Injection Pump

On Stanadyne rotary pumps:

1. Slightly loosen fuel return line connector (A) at fuel

injection pump.

2. Operate fuel supply pump primer lever until fuel,

without air bubbles, flows from fuel return line
connection.

3. Tighten return line connector to 27 N•m (20 lb-ft).

4. Primer lever is spring-loaded and will return to normal

position.

OURGP11,000000D

–19–18OCT06–5/7

RG7948

–UN–13NOV97

Lucas Rotary Fuel Injection Pumps

B—Bleed Screw
C—Screw

On Lucas rotary pumps:

1. Loosen bleed screw (B) on pump cover.

NOTE: On Models DP200/201/203 Injection Pumps,

bleed screw is located on top of cover near the
fuel return line.

2. Operate fuel supply pump primer lever or turn ignition

switch to “ON”.

3. Wait until fuel flow is free of air bubbles. Tighten bleed

screw.

4. Primer lever is spring loaded and will return to normal

position.

CAUTION: NEVER loosen screw (C) securing
pump head, otherwise pump damage may
occur.

Continued on next page

45-13

110306

PN=118