Engine Operating Guidelines

OURGP12,0000076

–19–09SEP04–3/4

RG7961B

–UN–22JAN99

Changing Oil And Oil Filter Before First 250 Hours

4. During the first 20 hours, avoid prolonged periods of

engine idling or sustained maximum load operation. If
engine will idle longer than 5 minutes, stop engine.

5. Before the first 250 hours (maximum), change engine

oil and replace engine oil filter. (See CHANGING
ENGINE OIL AND REPLACING OIL FILTER in
Lubrication and Maintenance/250 Hour/6 Month
Section.) Fill crankcase with the normal seasonal
viscosity grade oil. (See DIESEL ENGINE OIL, in
Fuels, Lubricants, and Coolant Section.)

NOTE: Some increase in oil consumption may be

expected when low viscosity oils are used. Check
oil levels more frequently.

If air temperature is below -10

°

C (14

°

F), use an

engine block heater.

OURGP12,0000076

–19–09SEP04–4/4

RG11299F

–UN–17AUG00

North American (1999— ) Instrument Panel Shown

A—Coolant Temperature Gauge

6. Watch coolant temperature gauge (A) closely. If

coolant temperature rises above 112

°

C (234

°

F), reduce

load on engine. Unless temperature drops quickly, stop
the engine and determine the cause before resuming
operation.

NOTE: When the coolant temperature gauge reads

approximately 115

°

C (239

°

F), the engine will

shutdown automatically, if equipped with safety
controls.

7. Check poly-vee belt for proper alignment and seating

in pulley grooves.