Engine Operating Guidelines

RG,RG34710,5563

–19–07JAN02–1/1

Stopping the Engine

RG11299J

–UN–11SEP00

North American Standard Instrument Panel Shown

RG10616

–UN–16JUN00

Exhaust Stack Rain Cap

A—Throttle
B—Key Switch

1. Disengage clutch (if equipped) controlling engine

drivelines.

2. Move the throttle (A) to slow idle on standard

(mechanical) governor engines.

IMPORTANT: Before stopping an engine that has

been operating at working load, idle
engine at least 2 minutes at 1000–1200
rpm to cool hot engine parts.

For engines in generator set
applications, where the governor is
locked at a specified speed and no slow
idle function is available, run engine for
at least 2 minutes at fast idle and no
load.

3. Turn key switch (B) to "OFF" position to stop the

engine. Remove ignition key.

IMPORTANT: Make sure that exhaust stack cap (rain

cap) is installed when engine is not
running. This will prevent water and dirt
from entering engine.