Cabling requirements for ni 9853, Cable specifications – National Instruments NI 9853 User Manual

Page 12

Advertising
background image

NI 9853 Operating Instructions

12

ni.com

Cabling Requirements for NI 9853

This section deals with cabling specifications, termination
resistors, cable lengths, and the number of CAN nodes that can
exist in a system.

Cable Specifications

Cables should meet the physical medium requirements specified in
ISO 11898, shown in Table 3. Belden cable (3084A) meets all of
those requirements, and should be suitable for most applications.

Table 3. ISO 11898 Specifications for Characteristics of a CAN_H and

CAN_L Pair of Wires

Characteristic

Value

Impedance

95

Ω minimum, 120 Ω nominal, 140 Ω maximum

Length-related
resistance

70 m

Ω/m nominal

Specific line delay

5 ns/m nominal

Advertising