Lifebreath 95MAX User Manual

Page 14

Advertising
background image

14

Press and hold the fan selection button on the Control Pad. After 5 seconds the control will
begin to cycle each mode holding each for 2 seconds. Release the button when the desired
mode of operation is reached.

Modes of Operation

LED Indication

OFF

No LED’s illuminated HRV/ERV is off, no controls will
initiate operation.

Standby / On

Steady Green LED and Yellow LED to indicate speed
HRV/ERV will run at speed selected in ventilation mode.
Standby mode is indicated by no speed indicator
illuminated. Optional remote controls will override standby
or selected speed into high speed.

20 On / 40 Off

Flashing Green LED and Yellow LED to indicate speed.
HRV/ERV will operate in ventilation mode at speed selected
for 20 minutes and OFF for 40 minutes.

Recirculation

Steady Red LED and Yellow LED to indicate Speed.

*Note: Not available on all models

HRV/ERV will operate in recirculate mode at the selected
speed. Optional remote controls will override unit into high
speed ventilate mode.

To select speed
Momentarily press fan selection button and release. HRV/ERV will move into next speed.
OFF is indicated by no yellow LED illuminated. Speed 1 is the first yellow LED. Speed five is
indicated by a flashing speed 4 LED.
Automatic Defrost
During cold outdoor conditions the HRV/ERV will occasionally go into an automatic defrost
function, which will prevent ice from forming on the core. Defrost is indicated by a flashing Red
LED indicator.

To select mode of operation for ControlAir 15

Which Mode of Operation is Best for Me?

BEST

Continuous low

Ensures continuous air exchange within the home.

speed operation

Air is always fresh and healthy.

Intermittent low

Ensures air within the home is exchanged with fresh

BETTER

speed operation

outside air a minimum of 20 minutes each hour.

20 ON / 40 OFF

Allows unit to run on demand from remote controls such

GOOD

Standby mode

as DET Timer and Dehumidistat.

Advertising