5

Removably

Heat Recovery

Core

Drain Pan

Drain spout

FRONT

TOP

knockout for

side mounting of

EXHAUST return port

6" round collar

converted to oval

minimum

18 inches (459 mm)

required for

service access

Threaded

inserts (4)
at corners

SUPPLY
Fresh air

from outside

5" round collar

SUPPLY
Fresh air

to building

6" round

(conv. to oval)

collar

EXHAUST

Stale Air

to outside

5" round collar

EXHAUST

Return air

from building

Choice of port location

Knockouts on top and

side of unit (use 1 only)
6" round (conv. to oval)

collar supplied

18.5"

(470 mm)

18.5"

(470 mm)

16"

(406 mm)

SIDE

Hanging

straps (4)

24.5"

(622 mm)

Model

ENGINEERING DATA

THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE
The cross-flow heat recovery core transfers heat between the two
airstreams. It is easily removed for cleaning or service.

MOTORS AND BLOWERS
Each air stream has one centrifugal blower driven by a common PSC motor.
5 speed fan operation. 120 VAC, .8 Amps.

FILTERS
Washable air filters in exhaust and supply air streams.

MOUNTING THE HRV
Four threaded inserts at corners of the cabinet designed to accept PVC rein-
forced polyester straps that are supplied with the unit.

DEFROST
Recirculating defrost system.

CASE
Twenty gauge prepainted galvanized steel (G60) for superior corrosion resis-
tance. Insulated to prevent exterior condensation.
Drain connections 2 - 1/2" (12 mm) OD.

CONTROLS - ControlAir 15 - Standby/ON mode, 20 ON/ 40 OFF mode,
Recirculation mode, (each mode has 5 speeds). Control pad can be removed
from HRV and remotely mounted.

WEIGHT 52 lbs. (23.6 kg) SHIPPING WEIGHT 56 lbs. (25.4 kg)

OPTIONS

99-104 Digital Electronic Timer - 20/40/60 min.
99-105 Programmable Ventilation Control (PVC)

includes Programmable Time Clock, Dehumidistat and
Air Sentry™

99-109 Air Sentry™ Air Quality Monitor designed to accept

remotely mounted Control Pad

99-250 Ventilation Dehumidistat - Dehumidistat designed

to accept remotely mounted Control Pad

99-163 Duct Heater w/ Electronic SCR Thermostat, 1 Kw, 6”

(150 mm)

99-185 Weatherhoods, Two - 5” (125 mm) c/w 1/4” (6 mm)

mesh screen

WARRANTY

Units carry a LIFETIME warranty on the heat recovery

core and a 5 year replacement parts warranty.

TI-113-NE

1203

95MAX FANCURVE

100

75

50

25

0.1

0.2

0.3

0.4

0.5

Air Flo

w

(cfm)

Static Pressure (inH

2

0)

4

3

2

1

5

HIGH SPEED

MEDIUM HIGH SPEED

MEDIUM SPEED

MEDIUM LOW SPEED

LOW SPEED

4

5

3

2

1

*

*

Manufacturers Data

PERFORMANCE

HVI CERTIFIED

Net supply airflow in cfm (L/s) against external static pressure

E.S.P

cfm

L/s

@ 0.1” (25 Pa)

89

(42)

@ 0.2” (50 Pa)

78

(37)

@ 0.3” (75 Pa)

64

(30)

@ 0.4” (100 Pa)

36

(17)

Maximum Temperature Recovery

74%

Sensible Effectiveness
@ 64 cfm (30 L/s)

(CSA C439M)

74%

Sensible Efficiency
@ 64 cfm (30 L/s) 32˚F (0˚C)

64%

Sensible Efficiency
@ 64 cfm (30 L/s) -13˚F (-25˚C) 58%

VAC @ 60HZ

120

WATTS / Low speed

35

WATTS / High speed

136

Amp rating

0.8

DIMENSIONS 95MAX

inches (mm

)

All units conform to
CSA and UL standards.

511 McCormick Blvd.

270 Regency Ridge,

Suite 210

London, Ontario N5W 4C8

Dayton, Ohio 45459

T (519) 457-1904

T (937) 439-6676

F (519) 457-1676

F (937) 439-6685

Email: [email protected] Website: www.lifebreath.com

Advertising