Network Technologies NODEMUX ST-NXM-U-HD User Manual

Page 23

Advertising
background image

19

9) Read

Connection

for KVM Output/User

- read what input is connected to the specified output (KVM ports only)

a) Read Connection for Audio Output/User

- read what input is connected to the specified output (Audio ports only)

b) Read Mute Status and Volume for Audio Output/User

- read the volume and the mute status of the specified output (Audio ports only)

c) Read Unit Size

- read the switch size (number of inputs and outputs)

d) Read Unit Version/Revision String

- read a string containing the switch version, type, and size

e) Save I/O Connections into Unit Memory

- save the connections into switch memory bank

f)

Restore I/O Connections from Unit Memory

- restore the connections from switch memory bank

g) Save All Units I/O Connections into Units Memory

- save the connections into switch memory bank, command for all switches

h) Restore All Units I/O Connections from Units Memory

- restore the connections from switch memory bank, command for all switches

i)

Change All Units Baud Rate (9600/COM1:)

- change RS-232 Baud rate of all switches
- the current baud rate and serial port are displayed in parentheses

SET OPTIONS

1) select Com port current: (COM1:)

- select PC serial port
- the current PC serial port is displayed in parentheses

2) select Baud rate current: (9600)

- select PC serial port baud rate
- the current baud rate is displayed in parentheses

3) set unit Address current: (1)

- select the unit address
- the current address is displayed in parentheses

For any selection that requires user input, the user is prompted. When commands are sent to the matrix unit, the command string
and matrix unit responses are echoed to the screen. All commands generated by the program are formatted according to the
information provided in sections above. If any transmission problems are detected, an error message is displayed.