Operating environment, Storage environment, Shock and vibration – National Instruments NI PXI-8104 User Manual

Page 53

Advertising
background image

Appendix A

Specifications

© National Instruments Corporation

A-3

NI PXI-8104 User Manual

Operating Environment

Ambient temperature range.................... 5 to 50 °C in an NI PXI-1042

chassis (Tested in accordance
with IEC-60068-2-1 and
IEC-60068-2-2). Refer to the
datasheet linked from the
NI PXI-8104 Embedded
Controller product page
at

ni.com

for other

controller/chassis combinations.

Relative humidity range ......................... 10% to 90%, noncondensing

(Tested in accordance with
IEC-60068-2-56.)

Caution

Clean the NI PXI-8104 with a soft nonmetallic brush. Make sure that the device

is completely dry and free from contaminants before powering-on the controller again.

Storage Environment

Ambient temperature range.................... –40 to 65 °C (Tested in

accordance with IEC-60068-2-1
and IEC-60068-2-2.)

Relative humidity range ......................... 5% to 95% noncondensing

(Tested in accordance with
IEC-60068-2-56.)

Shock and Vibration

Operational shock .................................. 30 g peak, half-sine, 11 ms pulse

(Tested in accordance with
IEC-60068-2-27. Test profile
developed in accordance with
MIL-PRF-28800F.)

Random vibration

Operating ........................................ 5 to 500 Hz, 0.3 g

rms

(with solid-state hard drive)