Power – National Instruments NI 5422 User Manual

Page 30

Advertising
background image

NI 5422 Specifications

30

ni.com

Power

Figure 13. 5 V Current Versus Frequency and Amplitude

Table 12.

Specification

Typical Operation

Overload Operation

Comments

+3.3 VDC

2 A

2 A

Typical
Operation is Sine
Output, with
Analog Filter,
50

Ω termination.

200 MS/s High
Resolution
Sample Clock.
Digital Pattern
enabled and
terminated,
Sample Clock
routed to PFI 0
and terminated.

Overload
Operation occurs
when CH 0 is
shorted to
ground.

+5 VDC

Refer to Figure 13

2.7 A

+12 VDC

0.46 A

0.46 A

–12 VDC

0.01 A

0.01 A

Total Power

12.2 W + 5 V * 5 V Current

25.7 W

Frequency (MHz)

Sine Amplitude (Vpp into 50

)

0

2

4

6

8

10

12

0

10

20

30

40

50

60

70

80

2.6 A

2.3 A

2.0 A

Not Recommended