Installing the dfc in the nam, Installing the dfc in the nam 8 – Nortel Networks NORSTAR P0886634 User Manual

Page 14

Advertising
background image

8

Installing the DFC on systems equipped with DVCs

FAX Installation Guide

P0886634 Issue 1.0

Figure 4 Removing the front cover

Installing the DFC in the NAM

1. Make sure you are wearing your antistatic grounding strap. Ground yourself

by attaching one end of the grounding strap to your wrist and the other end to
a grounded metal surface.

2. If you are installing FAX on an earlier NAM, locate slot 7 on the expansion

bus. Remove the slot cover screw and the metal slot cover from the slot. Refer
to

Figure 5

on page 9.

If you are installing FAX on a NAM II, locate slot 8 on the expansion bus.
Remove the slot cover screw and the metal slot cover from the slot. Refer to

Figure 6

on page 9.

Keep the metal slot cover and screw. You must re-install the metal slot cover
if you remove the DFC.