GENERATOR FEATURES

Reference 1 - Circuit Breakers. This belt driven

single phase generator has 2, 11 amp (A) push to
reset circuit breakers to protect against electrical
overloads.

Receptacles
Reference 2 - 120V Receptacle.
The generator

has a end cover with two duplexes (two receptacles in
a common housing). The duplex on the right is a 120
volt (V) 15 amp (A) straight blade receptacle, National
Electrical Manufacturer’s Association (NEMA) number
5-15R. This receptacle accepts NEMA plug number 5-
15P. Each receptacle on the duplex is capable of
drawing 11A.

Reference 3 - 240V Receptacle. The duplex on

the left is a 240V 15A NEMA 6-15R receptacle. This
receptacle accepts a NEMA plug number 6-15P.

ALWAYS use grounded male plugs. The neutral

line of the generator is mechanically grounded to the
frame. Matching NEMA male plugs must always be
used.

Reference 4 - Ground Screw . Ground the

generator via the ground screw, to a copper pipe or
rod that is driven into moist soil.

Reference 5 - 7/8” dia Shaft. The shaft is 1.50”

long and has a 3/16” keyway.

Reference 6 - Mounting feet. Use these three

locations to bolt the generator head in place.

Reference 7 - Fan Vents. Never block the vent

slots or insert objects through the slots.

INTRODUCTION

Before attempting to mount your generator,

thoroughly study the instructions and cautions in this
manual to assure you are fully acquainted with the
operation of all components of this generator. Proper
preparation, operation and maintenance will result in
operator safety, best performance and long life of the
generator.

North Star is constantly improving its products.

The specifications outlined herein are subject to
change without prior notice or obligation. The
purchaser and/or user assumes liability of any
modification and/or alterations on this equipment from
original design and manufacture.

Before using, the user shall determine the

suitability of this product for its intended use and
assumes liability therein.

ANSI SAFETY DEFINITIONS

DANGER

indicates an imminently hazardous

situation which, if not avoided, will result in death or
serious injury. This signal word is to be limited to the
most extreme situations.

WARNING

indicates a potentially hazardous

situation which, if not avoided, could result in a
death or serious injury.

CAUTION

indicates a potentially hazardous

situation, which if not avoided, may result in minor or
moderate injury. It may also be used to alert against
unsafe practices.

RULES FOR SAFE OPERATIONS

Safety precautions are essential when operating

this generator. Respectful and cautious operation will
considerably lessen the possibilities of a personal
injury. This manual will warn of specific personal injury
potential, and these will be designated by the symbol:

WARNING

This generator is equipped

with a grounding screw, located on the generator
frame for your protection. Always complete the
grounding path from the generator to a copper
pipe/rod that is driven into moist earth, to prevent
electrical shock.

ALWAYS use electrical cords that are in good

condition. Worn, bare, frayed or otherwise damaged
cords can cause electric shock.

NEVER operate the generator, or handle any

electrical equipment while standing in water, while
barefoot, while hands are wet or while in the rain or
snow. Electric shock may result.

ALWAYS use a ground fault circuit interrupter

(GFCI) in damp or highly electrical conductive areas
and on construction job-sites to prevent electric shock.

ALWAYS remove the spark plug or spark plug

wire before working on the engine or generator, to
prevent accidental starting.

ALWAYS provide adequate ventilation. Do not

operate generator in any enclosed or narrow space.
Engines consume oxygen and give off deadly carbon
monoxide poisonous gas. Improper ventilation will
cause damage to generator and possible injury to
people.

ALWAYS

remove all oil or gasoline deposits and

accumulated dirt from generator and immediate area.
Keep generator head and engine clean.