Generator care – North Star 2900 User Manual

Page 9

Advertising
background image

8

Output voltage should be checked periodically to

ensure continued proper operation of the generating
plant and appliances, it can be checked with a portable
meter. Frequency can be checked by using an electric
clock with a sweep second hand. Timed against a
wrist watch or a stop watch the clock should be correct
within +/- 2 seconds per minute. All speed setting
adjustments should be done by a qualified technician.

GENERATOR CARE

The generator head is a two pole, 3600 RPM, 60

Hz, brushless, revolving field and synchronous type
with two sealed radial roller bearings.

Proper care and maintenance are necessary to

ensure a long trouble free life.

Exercising The Generator - The generator

should be operated every three to four weeks. Warm
the unit up by starting the engine and letting it run for
10 to 15 minutes. This will dry out any moisture that
has accumulated in the windings. If left, this moisture
can cause corrosion in the winding. Frequent
operation of the engine generator will also ensure that
the set is operating properly should it be needed in an
emergency.

Generator Maintenance - The generator head is

brushless and maintenance free. Any major generator
service including the installation or replacement of
parts should be performed only by a qualified electrical
service technician. USE ONLY FACTORY
APPROVED REPAIR PARTS.

A. Bearing - The bearings used in this generators

are a heavy duty, sealed roller bearing. They require
no maintenance or lubrication.

B. Receptacles - Quality receptacles have been

utilized. If a receptacle should become cracked or
otherwise damaged, replace it. Using cracked or
damaged receptacles can be both dangerous to the
operator and destructive to the equipment.

WARNING, Stand-by Operation

If your generator is to be used as a standby

electric power source in case of utility failure, it must
be installed by a registered and licensed electrician
and in compliance with all applicable state and local
electrical codes. Also, local Fire Departments must be
consulted concerning proper and safe handling
procedures for gasoline. NEVER connect any
generator to any existing electrical system without an
isolating, UL approved transfer switch, installed by a
licensed electrician.