Talk/listen modes, Figure 2-2. possible settings for gpib-com jumpers, Figure 2-3. jumper w1 settings – National Instruments GPIB-COM User Manual

Page 16

Advertising
background image

Configuration and Installation

Section Two

GPIB-COM User Manual

2-4

© National Instruments Corporation

Figure 2-2 shows the four possible combinations of jumper settings.

XF8

3X8

IRQ4

XE8

2X8

IRQ3

W5

W2

a. COM1: Jumpers Set to Base I/O Address

3F8 hex and Interrupt Level 4 (Default)

XF8

3X8

IRQ4

XE8

2X8

IRQ3

W5

W2

b. COM2: Jumpers Set to Base I/O Address

2F8 hex and Interrupt Level 3

XF8

3X8

IRQ4

XE8

2X8

IRQ3

W5

W2

c. COM3: Jumpers Set to Base I/O Address

3E8 hex (Interrupts Not Used)

XF8

3X8

IRQ4

XE8

2X8

IRQ3

W5

W2

d. COM4: Jumpers Set to Base I/O Address

2E8 hex (Interrupts Not Used)

Figure 2-2. Possible Settings for GPIB-COM Jumpers

Talk/Listen Modes

If you are using your GPIB-COM with a listen-only printer or plotter, you can configure the
GPIB-COM for a talk-only mode. In this mode, the GPIB-COM is always a Talker and never
sends any interface commands. To set the talk-only mode, change jumper W1 from T/L to T as
shown in Figure 2-3:

W1

W1

T

T

T/L

T/L

a. Talk/Listen

(Default)

b. Talk Only

Figure 2-3. Jumper W1 Settings