15 Notice on K1 vacuum cleaners used for removing asbestos

A vacuum cleaner that has been used for removing asbestos in a contaminated area
may no longer be used in a non-contaminated area.

An exception is possible when the vacuum cleaner has been decontaminated
completely, that means not only the outside, but also the inside of the vacuum
cleaner (cooling air passages, the installation space for electrical resources or the
resources themselves). The persons in charge is obliged to write it down and sign a
protocol.

Fixed filters may only be replaced by skilled personnel special areas
(decontamination stations).

For a dust-free transport, the vacuum cleaner has to be emptied, the shutter cap of
the suction inlet has to be mounted, the exhaust outlets have to be closed (e.g. by
adhesive tape) and the lifting mechanism has to be locked.

The accessories in use have to be transported in closed plastic bags.

Use our exhaust air accessory kits to guide the exhaust air outdoors!

Art.no. 021 753 for 70 mm suction inlet
Reduction tube (Ø 100 mm)
5 m exhaust air hose (Ø 100 mm)

Art.no. 021 751 for 100 mm suction inlet
Reduction tube (Ø 150 mm)
5 m hose (Ø 150 mm)