W415-0244 / A / 05.15.03

Closing the air shutter will cause a more yellow flame, but
can lead to carboning.

Opening the air shutter will cause a more blue flame, but
can cause flame lifting from the burner ports. The flame
may not appear yellow immediately; allow 15 to 30 min-
utes for the final flame colour to be established.

Air shutter adjustment must only be done by a

qualified installer!

To access the air shutter, remove the two screws that se-
cure the cover to the air housing, taking care not to dam-
age the gasket.

Adjust the pilot screw to provide properly sized flame. Turn
in a clockwise direction to reduce the gas flow.

Air shutters have been factory set open according to the
chart below:

These settings are for the maximum horizontal vent run.
Adjustment may be required depending on fuel type, vent
configuration and altitude.

FIGURE 51

AIR SHUTTER

NG

3/32"

LP

3/16"

FIGURE 52

FIGURE 50

COVER

VENTURI

FIGURE 53

PILOT SCREW

LO

OT

PIL

IH

PL

O

O

FF

ADJUSTMENTS

PILOT BURNER ADJUSTMENT