Top exit / horizontal termination, 90° h, Elbow vent length values definitions – Napoleon Fireplaces BGD38PT User Manual

Page 9

Advertising
background image

9

W415-0244 / A / 05.15.03

for the following symbols used in the venting calcula-
tions and examples are:

>

- greater than

>

- equal to or greater than

<

- less than

<

- equal to or less than

H

T

- total of both horizontal vent lengths (

H

R

) and offsets

(

H

O

) in feet

H

R

- combined horizontal vent lengths in feet

H

O

- offset factor: .03(total degrees of offset - 90°

*

) in

feet

V

T

- combined vertical vent lengths in feet

feet

inches

0.03

0.5

15°

0.45

6.0

30°

0.9

11.0

45°

1.35

16.0

90°

*

2.7

32.0

*

the first 90° offset has a zero value and is shown in

the formula as -90°

when

(H

T

) < (V

T

)

Simple venting configuration (only one 90° elbow)

FIGURE 5

See graph to determine the required vertical rise

V

T

for the

required horizontal run

H

T

.

For vent configurations requiring more than one 90° el-
bow, the following formulas apply:

Formula 1: H

T

< V

T

Formula 2: H

T

+ V

T

< 40 feet

Example 1:

90°

90°

V

1

= 3 ft

V

2

= 8 ft

V

T

=

V

1

+

V

2

= 3 + 8 = 11 ft

H

1

= 2.5 ft

H

2

= 2 ft

H

R

=

H

1

+

H

2

= 2.5 + 2 = 4.5 ft

H

O

= .03(three 90° elbows - 90°) = .03(270° - 90°) = 5.4 ft

H

T

=

H

R

+

H

O

= 4.5 + 5.4 = 9.9 ft

H

T

+ V

T

= 9.9 + 11 = 20.9 ft

Formula 1:

H

T

< V

T

9.9 < 11

Formula 2:

H

T

+ V

T

< 40 feet

20.9 < 40

Since both formulas are met, this vent configuration is ac-
ceptable.

FIGURE 6

90°

H

1

V

2

H

2

V

1

ELBOW VENT LENGTH VALUES

DEFINITIONS

VERTICAL
R I S E I N
FEET

V

T

HORIZONTAL VENT RUN PLUS OFFSET IN FEET

H

T

The shaded area within the lines represents acceptable
values for H

T

and V

T

.

TOP EXIT / HORIZONTAL TERMINATION

Advertising
This manual is related to the following products: